Em Ramanujan – ER Series
+ Em Dian – ED Series
Super Advanced Edge
The Em Ramanujan also abbreviated as ER is a Super Advanced Edge Data logger, is a powerful Industrial Automation Controller which can be used for many complex automation tasks and is a comprehensive alternative to complicated & cost intensive PLC’s.
Two Versions:
- Em Ramanujan– Embedos Super Advanced Edge Data logger
- Em Dian– Embedos Super Advanced Edge Data logger with Display
Em Ramanujan ( ER Series ) - Super Advanced Edge Data logger
FEATURES | Em Ramanujan ( ER Series ) |
Category | Super Advanced Edge |
• Processor/ Speed | ARM-A53 1.2GHz Quad-Core |
• RAM | 1 GB RAM |
• Digital InputsL: (24V DC) PNP /(1 kHz) | 8 |
• Digital Outputs Isolated(SSR, 500 mA) | 6 |
• Analog Inputs (15 bit) Voltage ( 0/1 .. 10V, 1…10V) / Current (0/4 …20mA) | 4 (V/I field selectable) |
• Analog Output (12 bit) Voltage (0…10V, 1…10V) / Current (0…20mA, 4…20mA) |
1 (V/I Field selectable) |
• RS-485 Interface | 1, 2 / *Isolated * |
• RS-232 Interface | *Optional – Non – Isolated |
• RS-422 Interface | *Optional – Non – Isolated |
• CAN Bus Interface (CAN 2.0B with hardware filtering) | 1 |
• Buffer for Data storage | SD Card (8-32 GB) |
• USB Host / Device Port | 3 |
• Ethernet Interface | 1 (100 Mbps) |
• Wi-Fi Interface | IEEE 802.11 b/g/n Protocol: WEP, WPA, WPA2 (2.4 GHz) |
• GPRS Interface (2G/4G) | *Optional |
• GPS (GNSS systems: GPS, GLONASS, Galileo, Beidou) | *Optional |
• Bluetooth Interface (BLE) | *Bluetooth 4.1 (Bluetooth Classic and LE specification) |
• RTC | Yes |
• Remote acess | Login |
• Display | 1.6″ OLED Display |
• HDMI Output | HDMI (rev 1.3 & 1.4) |
• Field Protocols (Selectable) | Modbus RTU, Modbus TCP, Ethernet IP, Profibus Profinet IO , CAN Open, SAE J1939, OPC UA |
• IoT Connectivity Protocols | TCP I/P, HTTP, MQTT |
• Security (Encrypted Data Transmission Protocols) | HTTPS, MQTT with TLS |
• Encrypted Data Storage | Yes |
• Operating System | Linux |
• Programmability | Node-Red/ IEC 61131 |
• IEC 61131-3 Logic Control | Codesys |
• User Interface | Web Page on Embedded Web Server |
• Device Configuration | Web Page on Embedded Web Server |
• IO Channel Calibration | Web Page on Embedded Web Server |
• User management | Web Page on Embedded Web Server |
• Settable Alerts, Threshold Alarms | Web Page on Embedded Web Server |
• Operating Voltage | 24 VDC DC / * 100 to 240V AC |
• Operating Temperature | 0 to 60°C |
• Operating Humidity max. | 95%, non-condensing |
• RS485/RS232/GPRS/GPS Maximum | 3 |
• Thin Client Capability with USB Mouse, Keyboard Input & HDMI Output | Yes |
• Dimensions | 130X105X55 |
• Mounting | Surface /Rail |
• IP Rating | IP 20 |
Em Dian ( ED Series ) - Super Advanced Edge Data logger with Display
FEATURES | Em Dian ( ED Series ) |
• Processor/ Speed | ARM-A53 1.2GHz Quad-Core |
• RAM | 1 GB RAM |
• Digital InputsL: (24V DC) PNP /(1 kHz) | 8 |
• Digital Outputs Isolated(SSR, 500 mA) | 6 |
• Analog Inputs (15 bit) Voltage ( 0/1 .. 10V, 1…10V) / Current (0/4 …20mA) | 4 (V/I field selectable) |
• Analog Output (12 bit) Voltage (0…10V, 1…10V) / Current (0…20mA, 4…20mA) |
1 (V/I Field selectable) |
• RS-485 Interface | 1, 2 / *Isolated * |
• RS-232 Interface | *Optional – Non – Isolated |
• RS-422 Interface | *Optional – Non – Isolated |
• CAN Bus Interface (CAN 2.0B with hardware filtering) | 1 |
• Buffer for Data storage | SD Card (8-32 GB) |
• USB Host / Device Port | 3 |
• Ethernet Interface | 1 (100 Mbps) |
• Wi-Fi Interface | IEEE 802.11 b/g/n Protocol: WEP, WPA, WPA2 (2.4 GHz) |
• GPRS Interface (2G/4G) | *Optional |
• GPS (GNSS systems: GPS, GLONASS, Galileo, Beidou) | *Optional |
• Bluetooth Interface (BLE) | *Bluetooth 4.1 (Bluetooth Classic and LE specification) |
• RTC | Yes |
• Remote acess | Login |
• Display | 7” Reisistive Touch Screen Display |
• HDMI Output | HDMI (rev 1.3 & 1.4) |
• Field Protocols (Selectable) | Modbus RTU, Modbus TCP, Ethernet IP, Profinet IO, CAN Open, SAE J1939, OPC UA |
• IoT Connectivity Protocols | TCP, HTTP, MQTT |
• Security (Encrypted Data Transmission Protocols) | HTTPS, MQTT with TLS |
• Encrypted Data Storage | Yes |
• Operating System | Linux |
• Programmability | Node-Red/ IEC 61131 |
• IEC 61131-3 Logic Control | Codesys |
• User Interface | Web Page on Embedded Web Server |
• Device Configuration | Web Page on Embedded Web Server |
• IO Channel Calibration | Web Page on Embedded Web Server |
• User management | Web Page on Embedded Web Server |
• Settable Alerts, Threshold Alarms | Web Page on Embedded Web Server |
• Operating Voltage | 24 VDC DC / * 100 to 240V AC |
• Operating Temperature | 0 to 60°C |
• Operating Humidity max. | 95%, non-condensing |
RS485/RS232/GPRS/GPS Maximum | 3 |
Thin Client Capability with USB Mouse, Keyboard Input & HDMI Output | – |
Dimensions | 130X105X55 |
Mounting | Panel Mount |
IP Rating | IP 20 |
Now, Use ER with a Fully Integrated Codesys RunTime!
Physical Interfaces
• Digital Inputs | 7 |
• Digital Outputs Isolated | 6 |
• Analog Inputs | 4 (V/I field selectable) |
• Analog Output | 1 (V/I Field selectable) |
• RS-485 Interface | 2, Isolated |
• RS-232 Interface | Yes |
• RS-422 Interface | Yes |
• CAN Bus Interface | 1 |
• Ethernet Interface | Yes |
• Wireless Ethernet Interface | Yes |
• GPRS Interface (2G/4G) | Yes |
• Bluetooth Interface (BLE) | Yes |
• HDMI Output | Yes |
• USB Host / Device Port | 3 |
• In Built SD Card | Yes |
Use the ER as a soft PLC in the following industrial networks and many more standard protocols!
Highlights!
- Em Ramanujan is a powerful Industrial Automation Controller which can be used for many complex automation tasks and is a comprehensive alternative to complicated & cost intensive PLC’s.
- The Em Ramanujan functionality can be extended by adding multiple Embedos Expansion modules ( Em Maxwell Series ) of Analog & Digital IO’s, and many more serial communication interfaces on RS-485 & CAN.
- With The Codesys integrated Runtime, user interfaces & visualizations can be generated and displayed on PCs, tablets or smartphones via all common and interconnected browsers on the same network. This eliminates the need for separate HMI software.
- In addition to running the CODESYS Control runtime on the Em Ramanujan ( ER Series ), individual applications can of course still be installed or be programmed via Node-RED, Python or directly in C, among othersprogramming languages.
- The Em Ramanujan ( ER Series ) has a Codesys run time that inherently supports many fieldbus or Industrial Ethernet protocols such as PROFINET, EtherCAT, EtherNet/IP or CANopen, Modbus TCP & OPC – UA and thus enables the use of the ER as a soft PLC in such networks.
Our Experts Want to speak to You!
Find out how our Products & Solutions can efficiently monitor and control your assets in real time!
From Shop Floor to Top Floor
Help Us Help You Leverage the Power of Industrial IoT
Get in Touch Now!
Get In Touch, Now!
+91-2231933643
+91-8369241588
+91 8591839206
team@embedos.io
1, Varun Apartments, Santacruz West, Mumbai - 400054. India.
Monday-Saturday: 9am – 7pm